Phantom board configuration

   Examples for the DIP switches on the card.
   Switches read from left to right while viewing the
   card such that the text of the silkscreen is upright.
   Off Off Off Off  = 0x0200
   Off Off Off On   = 0x0220
   Off Off On  Off  = 0x0240
   Off On  Off Off  = 0x0280
   On  Off Off Off  = 0x0300 - recommended location
   On  On  On  On   = 0x03E0
   The card occupies 20 bytes of address space.

  example for commanding zero torque to motors
   note: 0     = -10 volts out (max reverse torque)
         32767 =   0 volts out
         65535 = +10 volts out (max forward torque)
  12 bit D/A converters, so lower 4 bits of this 16 bit command are 
  insignificant