Showing error 2154

User: Jiri Slaby
Error type: Reachable Error Location
Error type description: A specified error location is reachable in some program path
File location: product-lines/minepump_spec5_product54_safe.cil.c
Line in file: 282
Project: SV-COMP 2013
Project version: 2.6.28
Tools: Manual Work
Entered: 2013-01-17 16:57:54 UTC


Source:

 252#line 253 "Environment.c"
 253    retValue_acc = 0;
 254#line 255
 255    return (retValue_acc);
 256  }
 257#line 262 "Environment.c"
 258  return (retValue_acc);
 259}
 260}
 261#line 67 "Environment.c"
 262int isLowWaterSensorDry(void) 
 263{ int retValue_acc ;
 264
 265  {
 266#line 284 "Environment.c"
 267  retValue_acc = waterLevel == 0;
 268#line 286
 269  return (retValue_acc);
 270#line 293
 271  return (retValue_acc);
 272}
 273}
 274#line 1 "wsllib_check.o"
 275#pragma merger(0,"wsllib_check.i","")
 276#line 3 "wsllib_check.c"
 277void __automaton_fail(void) 
 278{ 
 279
 280  {
 281  goto ERROR;
 282  ERROR: ;
 283#line 53 "wsllib_check.c"
 284  return;
 285}
 286}
 287#line 1 "Test.o"
 288#pragma merger(0,"Test.i","")
 289#line 8 "Test.c"
 290int cleanupTimeShifts  =    4;
 291#line 11 "Test.c"
 292#line 20 "Test.c"
Show full sources